Fluke 117 600V Electricians Voltage Multimeter
The Fluke 117 Digital Multimeter includes integrated non-contact voltage detection to help get the job done faster
Designed by electricians and engineered by Fluke, the Fluke 117 is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools. With its integrated non-contact voltage detection, Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage, the Fluke 117 is a great choice for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min/Max/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.
Features:
- Accurate, easy-to-use multimeter with integrated VoltAlert™ technology for non-contact voltage detection
- Features AutoVolt automatic AC/DC voltage selection
- Provides low input impedance to help prevent false readings due to ghost voltage
- Presents a large white LED backlight for working in poorly lit areas
- Features True RMS capabilities for accurate measurements on non-linear loads
Specifications:
- Maximum voltage between any terminal and earth ground: 600 V
- Surge protection: 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
- Fuse for A input: 11 A, 1000 V FAST Fuse (Fluke PN 803293)
- Display: Digital: 6,000 counts, updates 4 per second
- Bar graph: 33 segments, updates 32 per second
- Operating temperature: -10°C to +50°C
- Storage temperature: -40°C to +60°C
- Battery type: 9 volt Alkaline, NEDA 1604A / IEC 6LR61
- Battery life: 400 hours typical, without backlight
- Size: 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
- Weight: 550 g
- Warranty: 3 years
- Accuracy Specifications
- DC millivolts
- Range/resolution: 600.0 mV / 0.1 mV
- Accuracy: ±([% of reading] + [counts]): 0.5% + 2
- DC volts
- Range/resolution
- 6.000 V / 0.001 V
- 60.00 V / 0.01 V
- 600.00 V / 0.1 V
- Accuracy: ±([% of reading] + [counts]): 0.5% + 2
- Auto volts
- Range/resolution: 600.0 V / 0.1 V
- Accuracy:
- 2.0% + 3 (DC, 45 Hz to 500 Hz)
- 4.0% + 3 (500 Hz to 1 kHz)
- AC millivolts¹ True RMS
- Range/resolution: 600.0 mV / 0.1 mV
- Accuracy:
- 1.0% + 3 (DC, 45 Hz to 500 Hz)
- 2.0% + 3 (500 Hz to 1 kHz)
- AC volts¹ True RMS
- Range/resolution
- 6.000 V / 0.001 V
- 60.00 V / 0.01 V
- 600.0 V / 0.1 V
- Accuracy
- 1.0% + 3 (DC, 45 Hz to 500 Hz)
- 2.0% + 3 (500 Hz to 1 kHz)
- Continuity
- Range/resolution: 600 Ω / 1 Ω
- Accuracy: Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
- Ohms
- Range/resolution
- 600.0 Ω / 0.1 Ω
- 6.000 kΩ / 0.001 kΩ
- 60.00 kΩ / 0.01 kΩ
- 600.0 kΩ / 0.1 kΩ
- 6.000 MΩ / 0.001 MΩ
- Accuracy: 0.9% + 1
- Range/resolution: 40.00 MΩ / 0.01 MΩ
- Accuracy: 5% + 2
- Diode test
- Range/resolution: 2.00 V / 0.001 V
- Accuracy: 0.9% + 2
- Capacitance
- Range/resolution
- 1000 nF / 1 nF
- 10.00 μF / 0.01 μF
- 100.0 μF / 0.1 μF
- 9999 μF / 1 μF
- 100 μF to 1000 μF
- Accuracy: 1.9% + 2
- Range/resolution: > 1000 μF
- Accuracy: 5% + 20%
- Lo-Z capacitance
- Range: 1 nF to 500 μF
- Accuracy: 10% + 2 typical
- AC amps True RMS (45 Hz to 500 Hz)
- Range/resolution:
- 6.000 A / 0.001 A
- 10.00 A / 0.01 A
- Accuracy 1.5% + 3
- 20 A continuous overload for 30 seconds max
- DC amps
- Range/resolution: 6.000 A / 0.001 A 10.00 A / 0.01 A
- Accuracy 1.0% + 3
- 20 A continuous overload for 30 seconds max
- Hz (V or A input)²
- Range/resolution
- 99.99 Hz / 0.01 Hz
- 999.99 Hz / 0.1 Hz
- 9.999 Hz / 0.001 Hz
- 50.00 Hz / 0.01 Hz
- Accuracy 0.1% + 2
Includes:
- 4 mm silicone test lead set
- Holster
- User manual